nav emailalert searchbtn searchbox tablepage yinyongbenwen piczone journalimg journalInfo journalinfonormal searchdiv searchzone qikanlogo popupnotification paper paperNew
2025, 10, v.20 846-855
基于FAHP-VIKOR耦合模型的高压电缆施工质量评价方法
基金项目(Foundation): 闽西职业技术学院横向科研项目(KYC2024022)
邮箱(Email):
DOI:
摘要:

为了提升电缆工程施工质量评价的韧性与动态性,以质量韧性为导向,构建模糊层次分析法(fuzzy analytic hierarchy process,FAHP)与多准则优化妥协解排序法(vlse kriterijumska optimizacija i kompromisno resenje,VIKOR)耦合评价模型。首先,建立涵盖电缆质量、施工工艺、人员技能、环境适应性4个维度、20项指标的评价体系。其次,采用韧性FAHP确定指标权重,通过动态VIKOR计算群体效用值(Si)、个体遗憾值(Ri)和利益比率(Qi),并基于Qi值排序。然后,以某铁路工程7个电缆施工标段案例进行验证,标段1在韧性指标上表现突出(Ri值为0.040),标段3整体稳定性最优(Si值为0.091),标段4则存在系统性质量缺陷。结果显示,该模型对电缆工程施工质量的评价与实际情况对比具有较高准确率,表明FAHP-VIKOR耦合模型可有效融合韧性指标与动态评价需求,对电缆工程施工质量作精准评估,为标杆标段经验推广及薄弱标段整改提供科学依据,对提升工程质量具有实践价值。

Abstract:

To enhance the resilience and dynamics of cable engineering construction quality evaluation, a coupled evaluation model of the fuzzy analytic hierarchy process(FAHP) and the vlse kriterijumska optimizacija i kompromisno resenje(VIKOR) was established under the guidance of quality resilience. Firstly, an evaluation index system covering 4 dimensions(cable quality, construction technology, personnel skills, and environmental adaptability) and 20 evaluation indicators was established. Secondly, the resilient FAHP was used to determine the indicator weights. The dynamic VIKOR was applied to calculate the group utility value(Si), individual regret value(Ri), and benefit ratio(Qi), with ranking based on Qi values. Subsequently, a case study was conducted on 7 cable construction sections of a railway. Section 1 performed prominently in resilience indicators with an Ri of 0. 040, while Section 3 achieved the optimal overall stability with an Si of 0. 091. Conversely Section 4 had systemic quality defects. The results show that the evaluation of cable engineering construction quality using this model has a high accuracy compared with the actual situation. The conclusion indicates that the coupled FAHPVIKOR model can effectively integrate resilience indicators with dynamic evaluation needs, providing accurate assessment for cable engineering construction quality. This work offers a scientific basis for promoting the experience of benchmark sections and rectifying weak sections, and has practical value for improving engineering quality.

参考文献

[1]徐冰. 10 kV电缆施工中的质量控制策略分析[J].电子技术,2021, 50(10):288-289.XU B. Analysis of quality control strategy in 10 kV cable construction[J]. Electronic Technology, 2021,50(10):288-289.(in Chinese)

[2]刘尚鹏,王丽霞,张雷.重型电缆敷设质量指标体系构建研究[J].科技与创新,2023(8):67-70.LIU S P, WANG L X, ZHANG L. Research on the construction of the quality index system for heavy cable laying[J]. Science and Technology&Innovation,2023(8):67-70.(in Chinese)

[3]舒服华.基于PROMETHEE的小区电缆线热缩指套质量评价[J].中国照明电器,2024(12):18-23.SHU F H. Quality evaluation of heat shrink finger sleeves for residential cable lines based on PROMETHEE[J]. China Light&Lighting, 2024(12):18-23.(in Chinese)

[4] QIAN Y J, PAN H Y, CHEN J, et al. Development of an explainable machine learning model for predicting device-related pressure injuries in clinical settings[J].BMC Medical Informatics and Decision Making, 2025,25(1):256.

[5] SUN N, ZHANG S, JIN P H, et al. An intelligent plate fin-and-tube heat exchanger design system through integration of CFD, NSGA-II, ANN and TOPSIS[J]. Expert Systems with Applications,2023, 233:120926.

[6] LI C Y, ZHANG L, XU Y, et al. A novel capacitybased approach for measuring alternative interactions in multicriteria decision analysis[J]. Journal of the Operational Research Society, 2024, 75(5):942-954.

[7]颜红艳,宁海,易欣.基于Delphi-IAHP-SPA-GCM的城市轨道交通项目运维韧性评价[J].铁道科学与工程学报,2025, 22(8):3680-3690.YAN H Y, NING H, YI X. Evaluation of operational and maintenance resilience of urban rail transit project based on Delphi-IAHP-SPA-GCM[J]. Journal of Railway Science and Engineering, 2025, 22(8):3680-3690.(in Chinese)

[8]綦方中,张磊磊.基于改进灰色预测模型的供应链韧性评价与预警研究[J].工业技术经济,2022,41(12):100-107.QI F Z , ZHANG L L. Research on evaluation and early warning of supply chain resilience based on improved gray forecasting model[J]. Journal of Industrial Technological Economics, 2022, 41(12):100-107.(in Chinese)

[9] GANDHI F R, PATEL J N. Groundwater potentiality deciphering and sensitivity study using remote sensing technique and fuzzy approach[J]. Acta Geophysica,2022, 70(1):265-282.

[10]高凯,左胜武,曾浩,等.基于组合权重模型对高压电缆绝缘料性能评价[J].现代塑料加工应用,2022,34(1):44-47.GAO K, ZUO S W, ZENG H, et al. Performance evaluation of high voltage cable insulation material based on combination weight model[J]. Modern Plastics Processing and Applications, 2022, 34(1):44-47.(in Chinese)

[11]施龙青,梁基业,翟培合.基于博弈论组合赋权的矿山地质环境评价[J].中国科技论文,2022, 17(9):1035-1042.SHI L Q, LIANG J Y, ZHAI P H. Evaluation of mine geological environment based on combination weighting of game theory[J]. China Sciencepaper,2022, 17(9):1035-1042.(in Chinese)

[12] RAYHAN D S A, BHUIYAN I U. A framework for evaluation of construction and demolition waste management alternatives using MCDA techniques in the context of Dhaka city[J]. International Journal of Construction Management, 2025, 25(4):481-493.

[13]王志平,张梦,傅敏,等.概率犹豫模糊环境下基于累积前景理论和VIKOR的多属性群决策方法[J].科学技术与工程,2023, 23(25):10649-10657.WANG Z P, ZHANG M, FU M, et al. Multi-attribute group decision making model based on cumulative prospect theory and VIKOR in probabilistic fuzzy environment[J]. Science Technology and Engineering,2023, 23(25):10649-10657.(in Chinese)

[14] FARROKHI R, EPACKACHI S, SADEGHIAN V.Effectiveness of various types of macro-modeling methods for reinforced concrete shear walls[J]. ACI Structural Journal, 2025, 122(4):189-204.

[15]罗依梦,孟景辉,许庆阳,等.轨道电路动态运行质量综合评价及应用[J].铁道标准设计,2022, 66(3):162-167.LUO Y M, MENG J H, XU Q Y, et al. Comprehensive evaluation and application of dynamic operation quality of track circuit[J]. Railway Standard Design,2022, 66(3):162-167.(in Chinese)

[16] ZHANG G X, LI M X, CHEN J X, et al. Research on the influence of the connection and withdrawal of a35 kV bypass system on the power quality of transmission lines[J]. Journal of Physics:Conference Series,2023, 2655(1):012028.

[17] SHANG Y Q, ZHAO Y, JI H Q, et al. Cable aging state diagnosis adapted from frequency-domain dielectric spectroscopy and polarization-depolarization current[J]. Energies, 2025, 18(12):3169.

基本信息:

中图分类号:TM752

引用信息:

[1]江松林,江林发,程千晟.基于FAHP-VIKOR耦合模型的高压电缆施工质量评价方法[J].中国科技论文,2025,20(10):846-855.

基金信息:

闽西职业技术学院横向科研项目(KYC2024022)